Clogged to clean: controlled flush to clear polymer skid
Removing residual polymer from complex transfer equipment requires more than a routine clean. With product trapped across pipework, pumps and hoses, the challenge is to restore equipment to a serviceable condition while preventing contamination, minimising waste and recovering materials wherever possible.
When a major UK operator needed residual polymer removed from a transfer skid and its associated hose network, ASCO planned and delivered a controlled diesel flushing operation within the wash bay. The work cleared the system, recovered the diesel for reuse and kept full environmental control from set-up through to demobilisation.
Client:
A major UK operator
Scope:
Environmental, Industrial Cleaning, Project Logistics
Location:
UK
Duration:
Work completed
At a glance
- Prepared the wash bay and inspected all hoses and equipment.
- Vacuumed residual product from hoses into an IBC for disposal.
- Set up the flushing circuit and monitored for leaks while client operators ran the diesel flush.
- Recovered the diesel and pumped it back for reuse.
Approach
We prepared the wash bay, then transported the diesel-filled 20 ft ISO tank, an empty 10 ft receiving tank, the polymer skid and the equipment basket from the laydown area and positioned them for the flush. All hoses and components were inspected before use, then residual product was vacuumed from the hoses and transferred into an IBC for disposal.
We then set up a controlled flushing circuit from the diesel tank, through the skid, to the receiving tank, with connections verified against the client’s operating instructions. Client personnel ran the skid to circulate diesel through the full system while we monitored for leaks.
After the flush, we recovered residual diesel by vacuum tanker and pumped the collected diesel back to the 20 ft ISO tank for reuse. The equipment was then cleaned, stored and secured for transport, and the work area was inspected and left clean.
Impact
The flush left the client with a skid and hose network they could return to service with confidence, free of the contamination risks that uncleared residue would have created. Careful planning and control at every stage showed that a complex flushing and recovery operation could be delivered without compromise.
- Residual polymer fully removed.
- Equipment restored to a clean, serviceable condition.
- Zero leaks, spills, environmental incidents or equipment damage.
- Disposal volumes reduced through diesel recovery.
- Delivered to site procedures and client instructions.